Proton Plus

Critical Care Ventilator
Complete care to critical patients.
  • PRVC/VS
  • APRV
  • SIMV-VC/PS
  • SIMV-PC/PS
  • CPAP & Bi-NIV-Non Invasive Ventilation
  • VS-Auto
  • PSV-Auto
User Friendly Concept :
  • Dual Display.
  • Large display showing all lung dynamics simultaneously on same screen.
    • Curves : Airway Pressure V/s Time, Tidal Volume V/s Time, Flow Rate V/s Time.
    • Loops : Airway Pressure V/s Flow Rate, Tidal Volume V/s Airway Pressure, Flow Rate V/s Tidal Volume.
  • Easy and Quick setting Keyboard.
Brochure - Proton Plus

Modes of Ventilation
  • Volume Control Modes : CMV - VC, ASSIST - VC, SIMV - VC/PS.
  • Pressure Control Modes : CMV - PC, ASSIST - PC, SIMV - PC/PS.
  • Advanced Modes : PRVC/VS, APRV.
  • Non - Invansive Modes : CPAP, Bi-NIV.
  • Auto Modes : PSV - Auto, VS - Auto.
Alarms : Preset and Settable
  • Airway Pressure : High, Low.
  • Inspired VT : High, Low.
  • Expired Volume : Low.
  • FIO2 : High, Low.
  • PEEP : High, Low.
  • Breaths Per Minute : High.
  • Apnea Alarm Time : 5 to 60 seconds.
Measured Parameters
  • No of Breaths : Spontaneous, Total Breaths per minute.
  • Airway Pressure : Peak, Plateau, Mean, PEEP.
  • Patient Trigger : Trigger Pressure, Trigger Flow.
  • Tidal Volume : Inspired Volume, Expired Volume.
  • O2 Concentration : Inspired FiO2.
  • Lungs Mechanics : Lung Compliance, Lung Resistance.
  • Minute Volume : Expired Minute Volume.
Settable Parameters
  • Breath per Minute (BPM) : Up to 120.
  • Tidel Volume (VT) :
    • Pediatric : 20 to 300cc.
    • Adult : 300 to 3000 cc.
  • Inspiratory Pressure : Up to 80 cm of H2O
  • PEEP : 0 to 35 cm of H2O
  • Inspiratory Pause : 0 to 50% of Ti
  • FiO2 : 21 to 100%
  • Pressure Trigger : -0.5 to -15 cm of H2O
  • Flow Trigger : 0.3 to 30 LPM
  • Apnea Back-up Time : 5 to 60 sec
Information on LCD
  • Parameters
    • Dynamic Airway Pressure Indication.
    • Mode, BPM, Spont. BPM, VTi ,VTe, PEEP, Ppeak, FiO2.
  • Curves & Loops
    • Airway Pressure v/s Time.
    • Tidal Volume v/s Time.
    • Flow Rate v/s Time.
    • Airway Pressure v/s Flow Rate.
    • Flow Rate v/s Tidal Volume.
    • Volume v/s Airway Pressure.
  • Display Size : 47 cms TFT LED Monitor.
Electrical and Gas Supply
  • Input Supply : 175 to 260 Volts OR 90 to 132 Volts AC, 50/60 Hz.
  • Internal Battery Back-Up : 90 Minutes.
  • External Battery : 10 to 15 Volts DC (Optional).
  • Power Consumption : 70 Watts (Approx.) for basic ventilator.
  • Gas Input : Medical Grade Air & O2 at 2.7 to 6 bar (39 to 87 psi).
  • Weight : 15 Kgs. (only Ventilator, without Cart).
Special Features
  • Nebulizer.
  • O2 Enrichment.
  • Manual Breath.
  • Standby Function.
  • Tube Compensation.
  • Inspiratory Hold.
  • Apnea Backup Ventilation.
  • Altitude Compensation.
Economy of Operation
  • Long Life Flow Sensor and FiO2Sensor.
  • Consumes least number of parts per patient.
  • Designed and built to operate in harsh environment.
  • Low Operational Cost per Patient.
  • Built to Last Long.


    Enquiry

    Your Name:
    Your Email-address:
    Your Contact Number:
    Message:

    Enquiry