Respimax

Emergency Care Ventilator
MAX MEDITECH offers microprocessor based technology in a compact, light weight portable multi-purpose ventilator system. Max Ventilators offer ease of operation, high functional reliability and consistency. They are electrically driven and do not require compressed air or oxygen. These advantages make max ventilators most ideal for hospitals where centralized oxygen facility is not available. Various monitaring alarms enable their usage in unattended applications.
  • Fully Electrically Driver.
  • Oxygen is not required as a driving source and hence wastage of gas is nil.
  • Can be used with a wide variety of Anaesthesia Circuits.
  • Inbuilt FiO2 Monitoring.
  • Long Life FiO2 Senior.
  • Colour TFT LCD Display.
  • Monitored Parameters on LCD.
  • Alarms for Critical Situations.
  • Ease of setting (User friendly Operations).
  • Visible Bellow.
  • Minimum Input, Output Connections.
  • Cost of ownership is minimum.
  • Tropicalized design - suitable for Indian environment.
  • Compact & Light Weight.
Brochure - Respimax
View more...

Operational Parameters
  • Operating Mode : CMV, ASSIST - APB, SIMV, CMV - PCV, ASSIST - PCV- APB, SIMV - PCV, ANAESTHESIA MODE.
Electrical and Gas Supply
  • Display : 3"5 TFT (320 x 240) Colour Display for Indications.
  • Input Connection : 22mm Female Port for Gas Intake.
  • Output Connection : 22mm Male Port for Gas Delivery.
  • Input Supply : 220/240 Volts, 50/60 Hz AC.
Monitored Parameters
  • Spontaneous Breaths.
  • Total Breaths.
  • FIO2.
  • Insp. Peak Pressure P-Peak.
  • Exp. End Airway Pressure PEEP.
  • Patienc Trigger Pressure.
Specifications
  • Fully Elccrrically Driver.
  • Oxygen is not required as a driving source and hence wastage of gas is nil.
  • Can be used with a wide variety of Anaesthesia Circuits.
  • Inbuilt FiO2 Monitoring.
  • Long Life FiO2 Senior.
  • Colour TFT LCD Display.
  • Monitored Parameters on LCD.
  • Alarms for Critical Situations.
  • Ease of setting (User friendly Operations).
  • Visible Bellow.
  • Minimum Input, Output Connections.
  • Cost of ownership is minimum.
  • Tropicalized design - suitable for Indian environment.
  • Compact & Light Weight.
Set Parameters
  • Breaths per Minute (BPM) : 1 - 60 (SIMV) & 6 - 60 (CMV & ASSIST).
  • Tidal Volume : 30-1100 cc (VC Modes).
  • L:E Ratio : 4:1 - 1:4.
  • Inspiration Time : 0.04 to 3.5 seconds.
  • Pressure Trigger : -0.5 to -15 cm of H2O below PEEP.
  • PCV pressure : 10 to 60 cm of H2O.
  • Inspiratory Hold Time : 15 to 35% of Ti.
  • Apnea Back-Up Time : 10 to 50 seconds.
Alarms
  • Low Insp. Pressure Limit (LIIP).
  • HIGH Insp. Pressure Limit (HIIP).
  • Low FIO2 (FIO2 L).
  • HIGH FIO2 (FIO2 H).
  • Apnea.
  • Disconnection.
  • Malfunction.
  • Excessive Inlet Gas Flow.
  • Insufficient Inlet Gas Flow.
  • Power Failure.
  • Pressure not Accained.


Enquiry

Your Name:
Your Email-address:
Your Contact Number:
Message:

Enquiry